Explore our full product range, project applications, and service areas in detail through our E-Catalogue. Our engineering-led solutions and internationally certified services are presented in this comprehensive reference document.
Heat Pumps and Heating
AstralPool Excellium Inverter is a full-inverter commercial heat pump delivering 45–185 kW of heating for hotels, sports facilities and public pools. With twin Mitsubishi compressors and R410A it reaches a COP of 5.9 at 28 °C air and 10.5 in Smart mode, heats at -15 °C outdoor air and also provides cooling.
EXC INV 30 · 45 kW · 380-415 V three-phase
Birden fazla ürünü listenize ekleyip hepsi için tek seferde teklif isteyebilirsiniz. Tek ürün için hemen teklif isteyin.
| Type | Full-inverter commercial heat pump (heating and cooling) |
|---|---|
| Heating output (28 °C air) | 45 – 185 kW (5 models) |
| COP (28 °C / 15 °C air) | 5.6 – 5.9 / 4.5 – 4.8 |
| Cooling output (30 °C air) | 23 – 92 kW · EER 3.4 |
| Min. operating temperature | -15 °C outdoor air |
| Power supply | 380-415 V / 3 / 50 Hz |
| Compressor | 2 × Mitsubishi inverter compressors |
| Refrigerant | R410A |
| Hydraulic connection | 63 / 90 mm |
| Noise level (10 m) | 40 – 48 dB(A) |
| Warranty | Compressor 5 years · titanium exchanger 7 years |
Values by order code
| Order code | |||||
|---|---|---|---|---|---|
| Nominal operating current (A) | 14.4 | 16.5 | 28 | 34.5 | 53 |
| Recommended water flow (m³/h) | 20 – 28 | 26 – 35 | 37 – 45 | 56 – 70 | 80 – 95 |
| Hydraulic connection (mm) | 63 | 63 | 90 | 90 | 90 |
| Pressure drop (kPa) | 30 | 32 | 35 | 38 | 46 |
| Refrigerant charge (kg) | 5.3 | 6 | 11 | 14 | 19 |
| Noise level at 10 m (dB(A)) | 40 | 42 | 43 | 44 | 48 |
| Noise level at 1 m (dB(A)) | 41 – 58 | 43 – 62 | 44 – 62 | 46 – 65 | 50 – 68 |
| Heating output – air 28 °C / water 28 °C / RH 80 % (kW) | 45 | 60 | 85 | 130 | 185 |
| COP – air 28 °C / water 28 °C / RH 80 % | 5.6 | 5.6 | 5.8 | 5.9 | 5.9 |
| SMART heating output – air 28 °C / water 28 °C / RH 80 % (kW) | 36 | 52 | 68 | 105 | 150 |
| SMART COP – air 28 °C / water 28 °C / RH 80 % | 10.3 | 10.4 | 10.5 | 10.5 | 10.5 |
| Power input – air 28 °C / water 28 °C / RH 80 % (kW) | 1.63 – 8.03 | 2.62 – 10.71 | 2.85 – 14.66 | 5.24 – 22 | 6.27 – 33.1 |
| Heating output – air 15 °C / water 26 °C / RH 70 % (kW) | 30 | 45 | 60 | 95 | 130 |
| COP – air 15 °C / water 26 °C / RH 70 % | 4.5 | 4.5 | 4.8 | 4.8 | 4.7 |
| SMART heating output – air 15 °C / water 26 °C / RH 70 % (kW) | 24 | 36 | 48 | 75 | 104 |
| SMART COP – air 15 °C / water 26 °C / RH 70 % | 7.4 | 7.5 | 7.9 | 7.9 | 7.8 |
| Power input – air 15 °C / water 26 °C / RH 70 % (kW) | 1.25 – 6.67 | 2.47 – 10.47 | 2.38 – 12.5 | 5.49 – 23.26 | 5.25 – 27.65 |
| Heating output – air -10 °C / water 26 °C / RH 78 % (kW) | 19 | 25 | 35 | 55 | 75 |
| Power input – air -10 °C / water 26 °C / RH 78 % (kW) | 6.6 | 8.7 | 12.1 | 19 | 26.7 |
| COP – air -10 °C / water 26 °C / RH 78 % | 2.9 | 2.9 | 2.9 | 2.9 | 2.8 |
| Cooling output – air 30 °C / water 26 °C (kW) | 23 | 30 | 43 | 64 | 92 |
| Power input – air 30 °C / water 26 °C (kW) | 6.8 | 8.8 | 12.7 | 18.9 | 27.9 |
| EER – air 30 °C / water 26 °C | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 |
| Cooling output – air 43 °C / water 26 °C (kW) | 15 | 20 | 28 | 41 | 60 |
| Power input – air 43 °C / water 26 °C (kW) | 5.6 | 7.41 | 10.4 | 15.2 | 23.1 |
| EER – air 43 °C / water 26 °C | 2.7 | 2.7 | 2.7 | 2.7 | 2.6 |
| Dimensions L × H × W (mm) | 866 × 1604 × 850 | 866 × 1604 × 850 | 1958 × 1699 × 968 | 1958 × 1699 × 968 | 2080 × 1830 × 1172 |
| Net weight (kg) | 290 | 294 | 560 | 590 | 810 |
| Order code | Variant description | Certifications |
|---|---|---|
| 75397 | EXC INV 30 · 45 kW · 380-415 V three-phase | — |
| 75398 | EXC INV 45 · 60 kW · 380-415 V three-phase | — |
| 75399 | EXC INV 60 · 85 kW · 380-415 V three-phase | — |
| 75400 | EXC INV 90 · 130 kW · 380-415 V three-phase | — |
| 75401 | EXC INV 130 · 185 kW · 380-415 V three-phase | — |
AstralPool Excellium Inverter is a full-inverter commercial heat pump delivering 45–185 kW of heating for hotels, sports facilities and public pools. With twin Mitsubishi compressors and R410A it reaches a COP of 5.9 at 28 °C air and 10.5 in Smart mode, heats at -15 °C outdoor air and also provides cooling.
Excellium Inverter is an aerothermal heat pump developed for hotels, campsites, sports clubs, public swimming pools, wellness, spa and water parks. It uses renewable energy from the ambient air: with a COP of up to 4.8 at 15 °C outdoor air it produces 4.8 kW of heat for every 1 kW of electricity consumed, and combined with green electricity it becomes a clean energy source.
Inverboost inverter technology in the compressors and fans keeps the water at the target temperature with minimal deviation, eliminates extra start-up consumption because it never has to restart at full power, and lowers noise to as little as 41 dB(A). Its reversible cycle lets it heat water at -15 °C outdoor air in winter and cool it in summer when needed; defrost is automatic by cycle reversal.
The titanium exchanger is compatible with every water treatment method. Its vertical axial fan can be connected to an exhaust air duct, so the unit can also be installed in a plant room. Turbo, Smart and Silent modes and heating, cooling and automatic operation are managed from the LCD control panel; the compressor carries a 5-year and the titanium exchanger a 7-year warranty.
Get a quote for Excellium Inverter Commercial Heat Pump
We select equipment together based on pool volume, turnover time and plant-room conditions.
We bring filters, pumps, chemicals and accessories together in a single quote.
Our engineering team answers your questions on model selection, capacity and compatibility.
We support you through installation, commissioning and periodic maintenance.